MULTI-PURPOSE HYDROMETERS (Cont'd)
- H-8375 Alcohol, Tralles and Proof
- Length: 310mm
- Standardization temperature: 60°F
- For testing spirits
| TRALLES | PROOF |
| RANGE % | DIVISION % | RANGE % | DIVISION % |
| 0 to 100 | 1 | 0 to 200 | 2 |
H-8425 Battery
- Length: 300mm
- Standardization temperature: 60° / 60°F
- For testing strength of fluids in storage batteries and other cells
- Float is 4 inches long
- Acid-resisting rubber bulb has capacity of approx. 1 oz.
- End piece has hard rubber tip
| SPECIFIC GRAVITY |
| RANGE | DIVISION |
| 1.100 to 1.300 | 0.005 |
H-8440 Battery
- Length: 457mm
- Standardization temperature: 60° / 60°F
- For testing strength of fluids in storage batteries and other cellls
- Similar to H-8425, but larger
- End piece has a square flange to prevent rolling
| SPECIFIC GRAVITY |
| RANGE | DIVISION |
| 1.150 to 1.300 | 0.005 |
H-8500 Propylene Glycol
- Length: 300mm
- Standardization temperature: 60° / 60°F
- For testing temperature of protection
- Float is 4 inches long
- Acid-resisting rubber bulb has capacity of approximately 1 oz.
- End piece has hard rubber tip
| RANGE | DIVISION |
| 32° to -46°F | 2° |
H-8575 Thermo-hydrometer, Brewing, Balling
- Length: 380mm
- Standardization temperature: 63.5°F
- Mercury filled
- For testing extract in wort
- Enclosed thermometer graduated from 0° to 130°F
| CAT. NO./ TYPE | RANGE | DIVISION |
| H-8575/BB-1 | 0°to 10° | 0.1° |
| H-8575/BB-2 | 10° to 20° | 0.1° |
| H-8575/BB-3 | 20° to 30° | 0.1° |
H-8576 Thermo-hydrometer, To ASBC Specification Percent Sugar by
Weight (Plato Scale)
- Calibrated for reading at bottom of meniscus and standardized at 14 Reaumur with
temperature correction scale for both brew house and laboratory
- Also called Balling Saccharameters
- Thermometer range: 0° to 40°R
- Mercury filled
| CAT. NO. / TYPE | RANGE/BALLING | DIVISION | LENGTH |
| H-8576 / 2515 | 0°to 81/2° | 0.1° | 255mm |
| H-8576 / 2516 | 7 1/2° to 16 1/2° | 0.1° | 255mm |
| H-8576 / 2517 | 16° to 24 1/2° | 0.1° | 255mm |
| H-8576 / 2500 | 0°to 14° | 0.1° | 350mm |
| H-8576 / 2501 | 0°to 24° | 0.1° | 425mm |
-
H-8625 Calcium Chloride
- Length: 310mm
- Standardization temperature: 60°F
- For testing calcium chloride
- With temperature correction chart
| RANGE | DIVISION |
| 0° to 120° | 1° |
H-8725 GLUE, BAUME
- Length: 300mm
- Standardization temperature: 120°F
- For testing glue (Baume Range)
| RANGE | DIVISION |
| 0° to 12° | 0.1° |
INDEX | ABOUT US | FAQ | OEM DESIGN | WHAT'S NEW