The first
non-mercury thermometer
with
the performance of mercury.
For information, click on the logo above.
New for
the Food Industry
HACCP
Compliance Kits
Standard HACCP Compliance Kit
#T-9000/Set
- One piece T-3750/63FFC, Miller & Weber precision certified thermometer, ASTM 63F.
This thermometer is used to calibrate the other thermometers in the set and is supplied with a NIST Traceable, ISO/IEC Guide 25 Accredited, Report of Calibration at: 20, 32, 50, 70, & 88°F.
- Three pieces T-220/3, 1 3/4" Dial Thermometer, 0/220°F, 2°Divisions with 5" stem.
Each thermometer is NSF® approved, has all stainless steel construction, a plastic water-tight dial, and a re-calibration hex nut.
- Four pieces FG80AK, Refrigerator & Freezer Thermometer, -40/80°F and -40/27°C.
Each thermometer is NSF® approved, will hang or stand, and has a magnifying lens cover.
- One storage box for all of the above.
Digital HACCP Compliance Kit
#T-9000D/Set
- One piece T-3750/63FFC, Miller & Weber precision certified thermometer, ASTM 63F.
This thermometer is used to calibrate the other thermometers in the set and is supplied with a NIST Traceable, ISO/IEC Guide 25 Accredited, Report of Calibration at: 20, 32, 50, 70, & 88°F.
- Three Pieces 300NSF/B Digital Thermometer, -40/300°F.
Each thermometer has Data Hold (D-H) button to freeze reading. Thermistor is sensitive enough that moving the unit even a few inches will change the reading. Press the D-H button to hold and record temperature, then press it again for continuous updates. Uses an AB13 button battery. Each thermometer is supplied witha rubber boot which makes it moisture/water resistant and ruggedized (shock resistant). NSF® approved with 5" stem.
- Four pieces FG80AK, Refrigerator & Freezer Thermometer, -40/80°F and -40/27°C.
Each thermometer is NSF® approved, will hang or stand, and has a magnifying lens cover.
- One storage box for all of the above.
NEW
108MM IMMERSION
PRECISION
CERTIFIED THERMOMETERS
SET OF NINE THERMOMETERS
INDIVIDUAL THERMOMETER
![]()
ASTM-LIKE PRECISION PARTIAL IMMERSION
OUR NEW (LIKE ASTM) SETS ARE MANUFACTURED IN EITHER CELSIUS OR FAHRENHEIT. EACH SET CONSISTS OF NINE THERMOMETERS, WHICH ARE INDIVIDUALLY ENGRAVED, ETCHED AND CALIBRATED FOR 108MM IMMERSION AGAINST STANDARDS CERTIFIED BY THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY.
EACH THERMOMETER IS CERTIFIED AT THE SAME FIVE VERIFICATION TEMPERATURES (LIKE ASTM). EACH THERMOMETER HAS AN ICE-POINT WHICH CAN BE USED TO CHECK THE VALIDITY OF THE CORRECTIONS AT ANY TIME. IT IS IMPORTANT TO NOTE THAT PURSUANT TO N.I.S.T. PUBLICATION #NIST/SP819 DATED AUGUST 1991, ANY PREVIOUSLY CERTIFIED THERMOMETER WITH A CALIBRATED ICE POINT NEED NEVER BE COMPLETELY RE-CALIBRATED. EACH SET OR INDIVIDUAL THERMOMETER COMES IN A LEATHERETTE, PLUSH-LINED CHANNEL CASE. REFILLS ALSO AVAILABLE, WITHOUT CASE (T-3755).
|
|
|
||||
| CAT. NO./ITEM |
|
|
|
|
|
| T-7755/62CFC | -38 TO 2°C | 0.1° | T-7755/62FFC | -36 TO 35°F | 0.2° |
| T-7755/63CFC | -8 TO 32°C | 0.1° | T-7755/63FFC | 18 TO 89° F | 0.2° |
| T-7755/64CFC | 25 TO 55°C | 0.1° | T-7755/64FFC | 77 TO 131° F | 0.2° |
| T-7755/65CFC | 50 TO 80°C | 0.1° | T-7755/65FFC | 122 TO 176°F | 0.2° |
| T-7755/66CFC | 75 TO 105°C | 0.1° | T-7755/66FFC | 167 TO 221° F | 0.2° |
| T-7755/67CFC | 95 TO 155°C | 0.2° | T-7755/67FFC | 203 TO 311° F | 0.5° |
| T-7755/68CFC | 145 TO 205°C | 0.2° | T-7755/68FFC | 293 TO 401° F | 0.5° |
| T-7755/69CFC | 195 TO 305°C | 0.2° | T-7755/69FFC | 383 TO 501° F | 1.0° |
| T-7755/70CFC | 295 TO 405°C | 0.5° | T-7755/70FFC | 563 TO 761° F | 1.0° |
| T-7755/6270CFC |
|
T-7755/6270FFC |
|
||

ISO PRECISION SERIES ALL INSTRUMENTS ARE 15" LONG, MADE OF 7-8MM O.D. YELLOW GLASS ENGRAVED, ETCHED AND CALIBRATED FOR TOTAL IMMERSION AND HAVE A RING TOP. EACH COMES COMPLETE IN A LEATHERETTE PLUSH LINED CASE WITH A REPORT OF CALIBRATION AT FIVE TEMPERATURES AND IS NIST TRACEABLE. THE COMPLETE SET HAS A RANGE OF -35/125°C. THIS RANGE (NOMINALLY 0/100°C) IS THE MOST UTILIZED BY END USERS COMPLYING WITH ISO 9000 SERIES STANDARDS.
EACH THERMOMETER HAS AN ICE-POINT WHICH CAN BE USED AT ANY TIME TO CHECK THE VALIDITY OF THE CORRECTIONS. THIS IS DONE BY TAKING THE ICE-POINT READING AND APPLYING ANY CHANGE TO THE CORRECTIONS ON THE SCALE. IT IS IMPORTANT TO NOTE THAT PURSUANT TO NIST PUBLICATION #NIST/SP-819 DATED AUGUST 1991, ANY PREVIOUSLY CERTIFIED THERMOMETER WITH A CALIBRATED ICE-POINT NEED NEVER BE RECALIBRATED.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|